A complete control bank and a cartridge are different orders

Replacing a full bank means buying the selected body and spool arrangement. A relief cartridge replaces one pressure-control component in the retained bank. Specify the operating function and installed number before comparing a bank price with a cartridge price.

Hydraulic valve purchase scope
ValveFunctionQuoted assembly
Main control bankRoutes flow to boom, arm, bucket, travel and swingComplete selected bank and controls
Pilot control valveCommands a main spoolPilot lever/pedal or valve unit
Overload/relief cartridgeControls pressure at one positionIndividual cartridge and its seals
Solenoid valveSwitches a commanded hydraulic functionCoil, cartridge or complete valve

YN22V00002F9 is an overload-valve assembly

The CNH YN22V00002F9 entry is an overload valve. Its shipping package is95 ×52 ×52mm and0.469kg, with one assembly per package. It belongs on a pressure-control purchase line, distinct from a complete main-valve bank.

Overload-valve order
FieldYN22V00002F9
ProductOverload valve assembly
Order unitOne valve
Shipping package95 ×52 ×52mm
Packaged weight0.469kg

Pilot and main valve numbers describe different components

702-16-03530 appears in the Komatsu PC200LC-8 pilot-control parts list as a PPC valve. The Cat6I-6899 is a legacy valve-group number for older320/325/330-series excavator entries. Keep the installed control position with either number; a PPC valve and a main bank are not the same assembly.

Ports, spool function and control voltage belong on the specification

For a complete bank, record the inlet and tank ports, actuator sections and pilot/control arrangement. For a cartridge, record the cavity/thread, sealing positions and set-pressure requirement. For a coil, give rated voltage, connector and coil code separately from the cartridge.

Valve matching fields
ItemTechnical purchase data
BankValve-group number, spool sections, inlet/tank and actuator ports
CartridgeCavity/thread, seal positions, function and pressure setting
Pilot unitPPC number, port arrangement and lever/pedal form
Solenoid coilVoltage, connector, coil code and retained cartridge

Pack a valve repair with its connecting seals

A replacement cartridge can travel with its seal set; a complete bank can include the required hose/pipe connection seals. Keep adapters and hoses as separate identified lines, especially on an order containing several machines.

Buying questions

Does an overload-valve price describe a whole control bank?

No. YN22V00002F9 is an overload-valve assembly. A full main bank includes its selected body and spool configuration.

Which voltage is needed on a solenoid order?

Use the installed coil voltage and connector code. The hydraulic cartridge has its own function and fitting identity.

Why does a relief cartridge need its pressure setting?

The valve controls pressure at an assigned circuit position. Its function and setting belong with the cavity/thread and sealing dimensions.

Can I replace only the coil?

A coil-only purchase retains the installed hydraulic cartridge. A complete solenoid-valve purchase identifies both the electrical and hydraulic components.